Palm Cooling with CryoTherm Palm Improves Sprint Performance in Football Athletes
byDella S
on
Authors:TherabodyScientists: Tim Roberts, MSc;Emily E. Munn, PhD, MEd;Rachelle Reed, PhD, MS, ACSM-EP
While competing in high-intensity sports, fatigue is inevitable. But how quickly it sets in can make the difference between solid andstrong performance.
Football players face repeated bouts of explosive effort throughout a match, so managing fatigue is critical. Palm cooling hasemergedas a promising recovery strategy,leveragingthe hand's unique vascular anatomy to rapidly dissipate heat and help athletes sustain performance across efforts.[1]
A new study conducted at IMG Academy in partnership with the University of Florida putsTherabody'sCryoTherm™ Palmto the test — measuring its impact on sprint performance, thermalperception, and perceived effort in highly trained U19 football athletes.
Here'swhat the study found.
Whytestpalm coolingforfootball athletes?
To testCryoThermPalm in a real-world athletic setting, Therabody turned to its partners at IMG Academy — one of the world's premier training institutions for elite youth athletes.IMG Academy's partnership withTherabodygives athletes direct access to the tools and technology to perform and recover at the highest level.
Footballis the most popular participatory sport in the world, with an estimated 240 to 270 million registered players globally.[2]It'sphysiologicallychallenging: the stop-and-go demandsofthe sportrequire repeated bursts of high-intensity effort.Previousresearch showsthat palm cooling is particularly effective atenhancing performance duringintense,intermittentefforts, making it a well-suited intervention for football players.[3]
What was the studyobjective?
Theobjectiveof the studywas to evaluate whether coolingthe palms between two6 x 30-meter sets ofsprintswith theCryoThermPalm device improvedrepeat sprint performance andreduced ratings ofperceived exertion.
Who were the study participants?
22 highly trained male football athletes, allunder 19 years old at IMG Academy in Bradenton, FL were recruitedand consentedtothe study.
How was the study conducted?
Thestudywas conducted atIMGAcademy.This study had a randomized crossoverdesign,andparticipantswere randomly assigned to the conditiontheywouldcomplete first.
Participants completedtheassigned condition on their first visit (either palm cooling betweensets ofsprints orpassive restbetweensets ofsprints). One week later, participants returned and completed the opposite condition.
All participants completed abrief,task-specific warm-up, delivered by the same IMG Academy coach at both sessions.Participantsthencompleted 2 sets of 6 × 30-meter sprints with 20 seconds of passive rest between repetitions and approximately 3.5 minutes of rest betweenthe twosets.The total protocoltook about 10 minutes per visit.
During the palm cooling intervention, participants used theTherabodyCryoThermPalm between sets of sprints, set to 12° C(54° F)for 2.5 minutes. During the control condition, the device was placed on the palms but remained off (thermo-neutral).
What did the study measure?
The study included several validated measuresof performance, including:
- Wellness and readiness:Hooper Index (sleep, stress, fatigue, muscle soreness) and Total Quality Recovery (TQR)datawerecollected beforeeachsession
- Thermal perception:Thermal sensation and comfort data werecollected during andimmediatelyafter the intervention, using a validated survey tool
- Sprint performance:Velocity, split time, and total sprint timecaptured by Vald timing gates
- Physiological load:Heart ratevia achest strap
- Rate of perceived exertion (RPE):RPE was collectedimmediatelyaftereachsprintset—anda higher scoreindicatesagreater perceivedeffort
What did the study find?
The study found that palm cooling with theCryoThermPalm device helped improve athletes'repeated sprintperformance, with significant results for top speed and sprint velocity. Palm cooling also helped athletes feel cooler and blunted the increase in perceived effort thataccompaniessets of repeated sprints.
There were no significant differences in pre-session readiness & recovery
Prior to each session,allathletes completedvalidated assessments for recovery, sleep, stress, fatigue, and muscle soreness.
No significant differences were found between conditions across any readiness metric, meaningathletes arrivedattestingin a comparable physiological and psychological state. Thishelpsrule out day-to-day variation in readiness as avariable thatimpactstheperformance outcomesobserved.
Athletes reported feelingcooler after usingCryoThermPalm
Using the AHRAE validated survey tool, athletes rated how hot or cool they felt during andimmediatelyafter the intervention, and the comfort of their experience.
Thermal sensation wassignificantlylower during and after the palm cooling intervention—athletes reportedfeeling60% coolerwithCryoThermPalm use.
Comfort scores did not significantly differ between conditions at any time point, suggesting that while athletes felt cooler after palm cooling,they feltcomfortableoverall.
Top speed and sprintvelocity significantly improved when palm cooling was used between sets
Sprint performance wasobjectivelyassessed across 12 trials (2 setsof6x 30-metersprints)using Vald timing gates.
Performance during thefinal 10 meters of a sprint tends to decline across repeated sprintsas fatigueaccumulates. When athletes used the palm cooling device, velocity declined by 6.9% from the first to the finalsprint, compared to an 11.6% decline in the control condition.This equated to a preservation in sprint velocity of 4.7%.
There were no significant differences between the palm cooling and control groups in the acceleration(0–10m)or transition phases(10–20m).
The palm coolingdevice alsopreservedtop-end speed quality.Athletes' top-end sprint velocity was 2.45% higher in the palm cooling condition, a statistically significant difference.While not statistically significant,athletes' split times trended faster in the final phase of each sprint.
Participantsexperienced a sharper rise in perceivedeffortwithout palm cooling
RPE rose to a greater extent in the controlconditionthan after palm cooling. While not reaching statisticalsignificance,the effectsizesindicatethat palm coolingmayhavehelped delay fatigue later in sprint sets.
Sprints feltharder byset 2, which is expected.But thedegree to which effortperceptionincreased wasdifferent: athletes without palm cooling experienced a sharper rise in perceived exertion as fatigue accumulated, despite completing identical workloads.
In the palm cooling condition, RPE increased by +0.62from set 1 to set 2, a medium effect size,reflecting a moderate change ineffort. Incontrast, duringthecontrolcondition,athletes’RPE increased by +1.07 over the same period, a large effect size, supportinganotableincrease ineffort.
No significant differences in heart rate were observed
Heart rate wasmonitoredcontinuously throughout both sets of sprints. No significant difference was found between conditions, confirming that athletes experienced equivalent physiological demand between the intervention and control conditions.
- Palm cooling with CryoTherm Palm helped preserve sprint velocity across repeated efforts, with a 4.7% advantage over the control condition by the final sprint
- Athletes usingCryoThermPalmmaintaineda 2.45% higher top-end sprint velocity compared to when they did not use palm cooling — a statistically significant difference
- Athletes felt 60% cooler after usingCryoThermPalm, while comfort scores remained similar between conditions
- Palm coolingslowedthe rise in perceived effort between sprint sets
- Heart rate did not differ between conditions, suggesting thatdifferences in cardiovascular load did not drive performance benefits